Short answer. We do not set coating thickness on our own. The owner’s named standard, its edition and the coating class define the required build-up, and the inspection records have to prove it.
- Ask the designer to state the standard, edition and class in the technical agreement before requesting prices.
- Thickness is verified per pipe with a documented procedure, plus holiday detection for dielectric coatings.
- Pipe-end cutback length and the field joint coating build-up are specified separately from the main body coating.
- Request sample thickness and holiday-detection records at the quotation stage so the format is agreed early.
Common references are AWWA C210, C213 and C215 plus ISO 21809; the version stated in the owner’s specification prevails.
On ADB- or World Bank-funded packages the thickness records are usually audited per pipe, so agree the record format and witness points at the quotation stage rather than at the loading port.