Specify the right pipe body standard, the right coating system and the right length for your container — in one place. Built for buyers of large-diameter SSAW / HSAW pipe.
The grade name belongs to the standard — "Grade B" in ASTM A106 and "Grade B" in ASTM A252 are not the same material. Always write the standard, grade and (for line pipe) the PSL level on the order.
| Application | Standard | Steel grades / designation | Key point |
|---|---|---|---|
| Oil & gas line pipe | API 5L / ISO 3183 (PSL1 / PSL2) | Gr A, B, X42, X46, X52, X56, X60, X65, X70, X80 | PSL2 adds mandatory impact toughness, carbon-equivalent limits and no repair welds; MTC to EN 10204 3.1 |
| Oil & gas line pipe (China) | GB/T 9711 | L245/B – L625/X90 | Chinese counterpart of API 5L |
| Water transmission | AWWA C200 | Steel water pipe, 6 in (150 mm) and larger; lining per C205 / C210 / C213 | Design guidance AWWA M11 |
| Water, Europe | EN 10224 | L235 / L275 / L355 | Non-alloy tubes for aqueous liquids; OD 26.9–2743 mm |
| Piling | ASTM A252 | Grade 1 / 2 / 3 — yield 205 / 240 / 310 MPa | Seamless or welded; longitudinal or helical seam allowed |
| Structural hollow sections | EN 10219 | S235JRH, S355J2H | Cold-formed welded sections — not a pressure pipe standard |
| Seamless, high temperature | ASTM A106 | Grade A / B / C — yield 205 / 240 / 275 MPa | Seamless only; power plants, refineries |
| Seamless / welded, general | ASTM A53 | Grade A / B; Type S (seamless), E / F (welded) | No Grade C; low-pressure fluid, plumbing, structural |
| Seamless pressure tube, Europe | EN 10216-1 / -2 | P195TR1, P235TR1/TR2, P265GH | Seamless pressure purposes |
| General fluid (China) | SY/T 5037 | Submerged-arc welded pipe for low-pressure fluid | Commonly cited for municipal water in China |
Grade A Grade B Grade C
Most requested: Grade B. Grade C allows higher carbon for higher strength.
Grade 1 Grade 2 Grade 3
Uses numbers, not letters. Grade 3 is common for large-diameter driven piles.
Grade B X42 X52 X60 X70
"X" = minimum yield in 1,000 psi. State PSL1 or PSL2 explicitly.
Need the PSL2 distinction explained? PSL2 Pipe: Definition, Process and Applications · What Does PSL2 Mean on a Steel Pipe Order?
Match the service condition first, then the coating. Every row assumes the base pipe has already passed weld NDT and hydrostatic testing — coating does not repair a base-pipe defect.
| Service condition | External protection | Internal protection | Notes for the purchase order |
|---|---|---|---|
| Buried water transmission main | 3PE (FBE / adhesive / PE) to DIN 30670 or ISO 21809-1 | Cement mortar or food-grade epoxy — specify separately | Define class, thickness, holiday test, bare-end cutback |
| Buried oil & gas line | Single or dual-layer FBE, or 3PE | Usually unlined; define internal cleanliness | Include cathodic-protection interface and field-joint coating |
| River crossing / marine transition | 3PE beneath Concrete Weight Coating (CWC) | Per project specification | CWC adds submerged weight, not corrosion protection |
| Water treatment plant piping | FBE or epoxy powder coating | Epoxy lining for potable water | Specify fittings and flange faces too |
| Piling / structural | Coal tar epoxy or project-specified | Not applicable | Bevel ends and transit damage protection matter more |
| Coating / lining system | Common governing standards | Typical service |
|---|---|---|
| 3LPE / 3PE (FBE primer + adhesive + PE) | DIN 30670, ISO 21809-1, GB/T 23257, CSA Z245.21 | Buried oil & gas and large water mains |
| 3LPP (polypropylene topcoat) | DIN 30678, ISO 21809-1 | Higher-temperature and deepwater service |
| FBE (single-layer fusion-bonded epoxy) | ISO 21809-2, CSA Z245.20, AWWA C213, AS 3862 | Plant-applied external line-pipe coating |
| 2LPE (adhesive + PE, no epoxy primer) | DIN EN 10288, ISO 21809-4 | General buried service |
| Liquid epoxy lining / coating | AWWA C210, NSF/ANSI 61 for potable water | Interior of water pipe, field repair |
| Cement mortar lining | AWWA C205 (shop), AWWA C602 (in place), EN 10298 | Large-diameter water transmission mains |
| Polyurethane coating / lining | AWWA C222, EN 10290 | Interior and exterior of steel water pipe |
| Field joint coating | ISO 21809-3, AWWA C216 (heat-shrink sleeves) | Site welding joints of coated pipe |
Coating protects the outside; the bore needs a separate lining. Specify the standard edition, class and thickness — "3PE" alone is not a complete order.
FBE primer + adhesive + PE topcoat. The blue bore here is a separate internal lining.
Fusion-bonded or liquid epoxy for potable water and water-plant piping.
Internal lining for large water mains, applied per AWWA C205 / project spec.
Enter pipe dimensions to estimate steel weight and the theoretical pieces that fit a 20ft or 40ft container. A planning aid, not a stowage plan.
Assumptions: steel density 7,850 kg/m³; usable section ≈ 2,350 × 2,390 mm; payload ceilings 28 t (20ft) / 26 t (40ft). Nesting or break-bulk (>28″) can change the result substantially.
Three references from completed work — a sanity check on diameter, length and inspection capability.
38,000 m DN600 spiral pipe, cement mortar + coal tar epoxy. 325 truckloads to Tianjin Port in two months.
EN 10224 L235 spools, D610 / D813, 11.8 m, PE + epoxy lining, third-party EU inspection.
DN1600–DN2000 super large-diameter pipe, epoxy lining, 100% UT + RT and hydrostatic testing.
3800 mm (about 150″) is the stated site-wide ceiling for SSAW / HSAW pipe. The exact OD / WT / coating combination is confirmed against the specific production line.
For line pipe: API 5L Grade B and X42–X80 (PSL1 / PSL2). For seamless: ASTM A106 Grade A / B / C. For piling: ASTM A252 Grade 1 / 2 / 3. Grade names differ by standard, so the full designation must be written on the order.
No. 3PE is external only — FBE primer, adhesive and PE topcoat. A buried water main still needs an internal lining such as cement mortar, liquid epoxy or polyurethane, specified separately.
PSL2 is the higher product specification level of API 5L, with tighter chemistry and mechanical properties and mandatory testing. See our PSL2 explanation.
Yes. SGS, BV, Intertek and TUV inspections can be included, with EN 10204 3.1 mill test certificates showing heat number, chemistry and mechanical results.
Name the base standard and grade, OD / WT / length, the 3PE standard and edition, coating class and layer thickness, bare-end cutback, internal lining, field-joint system and accepted tests.
As a rule of thumb, 5.80 m for 20ft and 11.80 m for 40ft. Use the calculator above for your actual diameter and wall thickness.
No email gate. Keep the two reference tables with your specification file.
Send us OD, wall thickness, steel grade, coating requirement and destination port. Our engineering team replies to custom RFQs within 12 hours.